V2 Shunt Calibration Deployment Plan
Objective
Update the live docker_tracker_hub calibration for PCB V2 to a nominal
0.130 ohm shunt. Preserve PCB V1 at 0.075 ohm, raw observations, historical
analysis and unrelated local or NAS changes. Do not modify firmware.
Execution
- Inspect the current local and NAS configuration, compose service and running container. Identify the active V2 device and any environment or persisted overrides that could retain the old resistance. Capture the current state needed to reverse only this deployment if verification fails.
- Apply the smallest local change and matching targeted NAS change. Add or update focused regression coverage for V2 current conversion and ensure V1 conversion remains unchanged. Run the available hub test suites.
- Build the new image while the current service remains running where the
deployment permits it. Recreate only
tracker-hub; do not usecompose down, remove volumes, overwrite directories or reset repository state. - Check the HTTP endpoint, container status, loaded V2 resistance, actual device version selection and live current conversion. Record any restart-related acquisition interruption. Report precisely if no live sample is available.
Acceptance Criteria
- The running hub selects
0.130 ohmfor the actual V2 device, not just for an unused default configuration entry. - V1 remains
0.075 ohmand unrelated board settings are preserved. - At the same raw current code and amplifier gain, V2 current is twice the value
obtained with the former
0.260 ohmconversion. - Relevant tests pass, and the hub is running and responds after deployment.
- Raw log files, databases, historical calibration metadata and the article's piecewise November 3 analysis are not rewritten or retroactively rescaled.
- No authentication secret is committed to source, documentation or memory.
Operational Limits
The experiment is already running. Minimize service interruption, but do not claim zero downtime without evidence. If validation fails, restore only the captured calibration/deployment state; preserve all newly collected data.
Ownership
The delegated implementation subagent completed the local calibration change and Python integration tests. After its interactive-authentication blocker, the main agent completed noninteractive SSH access, targeted NAS patching, deployment and independent live verification.
Execution Record
- Completed on 4 November 2026. New container started at
2026-11-04 16:34:44.608835 UTC(10:34:44on the NAS local clock). - Local change:
docker_tracker_hub/app/config.py; V2 is0.130 ohm, V1 remains0.075 ohm._fleet_test.pyverifies both absolute conversions and isolation. - All 23 fleet tests passed in the existing isolated Python environment. The telemetry parser test also passed. The dashboard suite was not run because Node.js was unavailable in the local environment; frontend code was unchanged.
- The actual NAS compose project is
/mnt/Fast/MICROTRACKING/docker-compose.yml, with build context/mnt/Fast/MICROTRACKING, not a nested hub directory. Only the V2 literal in/mnt/Fast/MICROTRACKING/app/config.pywas patched. - Built while the old container continued running, then deployed only
tracker-hubusingup -d --no-deps --no-build --wait --wait-timeout 60. - The new image is
sha256:a9772c3b08625f782577622a013c996c2efd268fdd1d7bedd412b1e66eeec0cb. Containeresp32_tracker_hubis healthy;/healthreports a readable store and no store-write error. - The actual device
esp32-000000000002reconnected as V2 and its live API reportsr_shunt=0.13. V1 deviceesp32-000000000001still reports0.075. - Verified live sample: raw current
4037629converts to379.13 mA, matching the independent formula. The same sample reports2.454 V,984.0 W/m2and762.80 mWestimated power. - The raw log remains in its existing bind mount. The samples bracketing the
restart are
10:34:38and10:34:59local time, a 21-second inter-sample gap. This is not a claim of zero acquisition downtime. - Rollback safeguards retained: source copy
/tmp/trackerhub-config-before-shunt130-b589a074eba193bc.pyand image tagmicrotracking-tracker-hub:pre-shunt130-20261104. No rollback was needed. - No firmware, raw historical observations, article analysis or persistent device identity/settings records were edited.